dc.description.abstract |
Modifications to the surface, structural and mechanical properties of brass have been
investigated by using three different kinds of radiation sources. The first radiation source was
laser, second one was laser induced plasma ions and the third one was Pelletron accelerator.
Brass targets were exposed to various laser pulses ranging from 1200 to 3000 of excimer laser
(248 nm, 20 ns, 120mJ and 30 Hz) at constant fluence of 6.4 J/cm2 in oxygen atmosphere (100
Torr). In order to explore the ion induced modification in properties of brass, ions were
generated by two different ion sources. The laser induced plasma was employed as a first ion
source for the generation of Ni, Si and C ions. Excimer laser (248 nm, 20 ns, 120mJ and 30 Hz)
was used for the generation of Ni, Si and C plasma. In order to estimate ion flux and energies,
Thomson parabola technique was employed. By using this technique, magnetic field of strength
80 mT was applied on the plasma plume to give appropriate trajectory to generated ions. These
ions were detected by solid state nuclear track detector (CR39). In response to stepwise increase
in number of laser pulses from 3000 to 12000, the Ni ion flux varies from 60 × 1013 to 84 × 1016
5
ions/cm2 with constant energy of 138 KeV. Similarly Si ion flux varies from 45 × 1012 to 75 ×
1015 ions/cm2 with constant energy of 289 KeV. The flux of C ions flux changes from 32 × 1011
to 72 × 1014 ions/cm2 with constant energy of 678 KeV. The second source of ion generation is
Pelletron accelerator. Brass targets were bombarded by Ni and C ions of energy 2MeV for
various ions flux ranging from 56×1012 to 26×1013 ions/cm2. Scanning Electron Microscope
(SEM) and X-Ray Diffractometer (XRD) were used to analyze the surface morphology and
crystallographic structure of irradiated brass respectively. Universal Testing Machine (UTM) and
Vickers Hardness Tester (VHT) were employed to explore Yield Stress (YS), Ultimate Tensile
Strength (UTS) and mirohardness of ion irradiated brass targets. SEM analysis reveals the
formation of micro/nano sized cavities, bumps, cones and wave-like ridges with non-uniform
shape and density distribution after laser irradiations. Whereas, ion irradiation causes the
formation and growth of nano/micro sized cavities, pores, pits, voids and cracks for lower and
moderate ion flux (in all cases). At maximum ion flux the granular morphology (in case of brass
irradiated by laser induced Ni and Si ions) and dendritic morphology (in the case of brass
irradiated by laser induced plasma and Pelletron accelerator C ions) are observed.
XRD analysis reveals that no new phases are identified in case of laser irradiated brass. However
new phases of CuZnNi (200), CuSi (311) and ZnC (0012) are identified in the brass substrate
after laser induced Ni, Si and C ions irradiation respectively. Whereas, no new phases are formed
in case of Ni and C ion irradiation obtained by Pelletron accelerator. The variation in peak
intensity, crystallite size, dislocation line density and induced stresses along with angular shifting
is observed in all cases of laser and ion irradiations. Significant variations in mechanical
properties of brass are observed after laser and ion irradiations. The changes in mechanical
properties of an irradiated brass are well correlated with surface and crystallographical
modifications and are attributed to generation, augmentation, recombination and annihilation of
the ion induced defects. The laser and ion induced surface, structural and mechanical
modifications of brass are significantly influenced by nature, energy and flux of radiations. |
en_US |