PASTIC Dspace Repository

Detection and adequacy assessment of erythrocyte glutathione transferase on the cycle toxin level of hemodialysis patient

Show simple item record

dc.contributor.author Qiu, Hui
dc.contributor.author Zhang, Dewei
dc.contributor.author Huo, Ping
dc.contributor.author Hong, Min
dc.contributor.author Zheng, Hongguang
dc.date.accessioned 2022-10-28T08:05:58Z
dc.date.available 2022-10-28T08:05:58Z
dc.date.issued 2015-09-06
dc.identifier.citation Qiu, H., Zhang, D., Huo, P., Hong, M., & Zheng, H. (2015). Detection and adequacy assessment of erythrocyte glutathione transferase on the cycle toxin level of hemodialysis patient. Pakistan Journal of Pharmaceutical Sciences, 28. en_US
dc.identifier.issn 1011-601X
dc.identifier.uri http://142.54.178.187:9060/xmlui/handle/123456789/13860
dc.description.abstract To explore detection and adequacy evaluation of erythrocyte glutathione S transferase (GST) in hemodialysis patients on circular toxin levels, this paper divided 84cases of long-term hemodialysis end-stage patients into 33 cases of adequate hemodialysis group (spKt/V≥1.3) and 51 cases of inadequate hemodialysis group (spKt/V<1.3) according to urea index value of unit chamber model (spKt/V). Take the other 50 cases of healthy physical examination people for control group, compare and analyze related clinical and biochemical indexes differences of three groups. The level of hemodialysis group GST, creatinine, high sensitivity C-reactive protein (hs-CRP), transferrin saturation (TSAT), parathyroid hormone (PTH), interleukin-2,6,8 (IL-2,6,8) and tumor necrosis factor-α (TNF-α) was significantly higher than the control group (P<0.05), and GST, IL-2, 6, 8, TNF-α level of inadequate hemodialysis group was significantly higher than adequate hemodialysis group (P<0.05). Pearson’s relevant analysis showed that GST and spKt/V, IL-2, IL-6, IL-8, TNF-α have positive correlation (P<0.05) and had no correlation with creatinine, hs-CRP, TSAT, PHT (P>0.05). There was 23patients spKt/V≥1.3 after adjusting the dialysis solution for 51cases of inadequate hemodialysis patients, GST level after the adjustment was significantly lower than before the adjustment, but still higher than adequate dialysis group. It concludes that the maintenance of hemodialysis patients’ level has certain relevance on spKt/V and associated inflammatory factors. Through the determination, GST can effectively response the adequate hemodialysis, which has a guiding significance on adjusting blood dialysis solution in clinic. en_US
dc.language.iso en en_US
dc.publisher Karachi:Pakistan Journal of Pharmaceutical Sciences, university of Karachi. en_US
dc.subject Hemodialysis en_US
dc.subject erythrocyte glutathione transferase en_US
dc.subject dialysis adequacy en_US
dc.subject inflammatory factor en_US
dc.title Detection and adequacy assessment of erythrocyte glutathione transferase on the cycle toxin level of hemodialysis patient en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account