PASTIC Dspace Repository

Etch Induction Time in CR-39 Detectors Etched in Na2CO3 Mixed NaOH Solution

Show simple item record

dc.contributor.author Ali, N.
dc.contributor.author Khan, E. U.
dc.contributor.author Khan, K.
dc.date.accessioned 2019-11-20T10:44:51Z
dc.date.available 2019-11-20T10:44:51Z
dc.date.issued 2009-01-01
dc.identifier.issn 26092901
dc.identifier.uri http://142.54.178.187:9060/xmlui/handle/123456789/1603
dc.description.abstract Six different solutions of 6M NaOH, containing different amounts of Na2CO3 at 70°C were used for the revelation of latent damage trails in CR-39 plastic track detectors. These detectors were earlier exposed to fission fragments from 252Cf source for 30 min in vacuum and were then etched in the respective solutions for different etching time intervals of 5–20 min starting from 5min up to 160min. The etch induction time in each detector was obtained by extrapolating the intersection of resulting curves of track lengths and track diameters with the time axis. en_US
dc.language.iso en_US en_US
dc.publisher Chinese Physical Society and IOP Publishing Ltd en_US
dc.subject Natural Science en_US
dc.subject Chinese Physics Letters Etch Induction en_US
dc.subject CR-39 Detectors en_US
dc.subject Na2CO3 en_US
dc.subject NaOH Solution en_US
dc.title Etch Induction Time in CR-39 Detectors Etched in Na2CO3 Mixed NaOH Solution en_US