dc.description.abstract |
This paper investigates the effect of variable reflux ratio on final product composition in a laboratory scale distillation column. The findings of this study include a minimum reflux ratio at which the highest purity of the product could be achieved. The experimental setup is a Technovate Distillation Column with five sieve plates, a feed tank, a reboiler, and a condenser. The feed and reflux ratio was varied with the help of flow meters associated with two centrifugal pumps. The feed composition was set to 45 percent ethanol-water mixture. The final composition obtained was 95% ethanol in the distillate. The minimum reflux ratio was found to be 60 percent of maximum flow. |
en_US |
dc.language.iso |
en_US |
en_US |
dc.publisher |
IEEE 2nd International Conference on Chemical, Biological and Environmental Engineering |
en_US |
dc.subject |
Engineering and Technology |
en_US |
dc.subject |
Binary distillation |
en_US |
dc.subject |
Reflux ratio |
en_US |
dc.title |
Effect of variable reflux ratio on binary distillation in a laboratory scale distillation column |