PASTIC Dspace Repository

Evaluation of performance parameters ofindigenously developed roots pumping system

Show simple item record

dc.contributor.author Maqsood, M.
dc.contributor.author Usman, A.
dc.contributor.author Bodla, M. F.
dc.date.accessioned 2019-12-16T06:36:34Z
dc.date.available 2019-12-16T06:36:34Z
dc.date.issued 2016-01-01
dc.identifier.issn 146 012047
dc.identifier.uri http://142.54.178.187:9060/xmlui/handle/123456789/1998
dc.description.abstract Roots pumping systems are widely used in industries to generate vacuum with high pumping speed. In the present work, the performance parameters of indigenously developed Roots pumping system have been studied. The performance parameters being studied are the ultimate pressure, working temperature, compression ratio and pumping speed. Ultimate pressure of the Roots pump after continuous running of eight hours is found to be 1.1×10-3 mbar. The most important parameter of the roots pump is the zero-gas flow c ompression Ratio(Ko) which is found to be 18 for the pumping system under study. Efficiency of Roots pump isfound to be 76% which is in good agreement as reported in the literature. en_US
dc.language.iso en_US en_US
dc.publisher IOP Conf. Series: Materials Science and Engineering en_US
dc.subject Natural Science en_US
dc.subject parameters of indigenously developed roots en_US
dc.subject pumping system en_US
dc.title Evaluation of performance parameters ofindigenously developed roots pumping system en_US
dc.type Article en_US