Abstract:
Maillard reaction is an imperative reaction that produces flavoring compounds in
various food items. Additionally, some toxic compounds are also formed during this non-
enzymatic reaction that mainly includes acrylamide and hydroxymethyl furfural. Current
research was conducted to detect the concentration of acrylamide production during
Maillard reaction in various model systems as well as in bakery items. Moreover, the
reduction of acrylamide concentration by using various mitigation strategies was also
included in the study plan. For the purpose, Maillard model systems were prepared by
utilization of amino acids and reducing sugars. Two amino acids, glutamine and
asparagine and two reducing sugars, glucose and fructose were taken and model systems
were prepared by heating the samples in Reflux apparatus for 1 hr followed by Clevenger
apparatus for 4-6 hrs in the presence of dichloromethane (solvent). About 1ml sample was
obtained by evaporation of separated solution in rotary evaporator. Then, acrylamide was
examined by using the technique of gas chromatography-mass spectrometry (GC-MS).
Subsequently, mitigation strategies like vacuum oven, calcium chloride and pectin were
applied on these model systems and acrylamide was analyzed. Maximum acrylamide
concentration was observed by GC-MS in control i.e., 22.37±1.9μg/g, while minimum
(3.51±0.5μg/g) was recorded in pectin-treated model system. On the basis of model
systems, minimum concentration (9.63±8.1μg/g) was examined in Fructose-Glutamine
model system. The two; pectin-treated Fructose/Glutamine (F/Gm) and
Glucose/Glutamine (G/Gm) model systems that contained very low amount of acrylamide
were selected for further safety and product analysis. For the safety assessment, two
selected model systems were added in water as 0.5 and 1% concentration and given to
four groups of Sprague-Dawley rats. Control model system, F/Gm that contained less
amount of acrylamide was given to the fifth group. Serum analysis, liver function tests,
protein tests and renal function tests were performed. It was revealed that minimum
values of AST and ALT were observed in group 2 (0.5% pectin-treated G/Gm model
system) i.e., 85.33±3.5 and 71.00±3.0IU/L, respectively due to less acrylamide formation.
Minimum serum total protein was recorded as 4.73±0.1g/dL in group 3 (1% pectin-
treated G/Gm model system), correspondingly. Minimum A/G ratio (0.87±0.12) was
recorded in group 1 (control) due to high acrylamide production. Urea explicated
significant variation from group 1 (control) to group 5 (1% pectin-treated F/Gm model
system) i.e., 92.67±4.0 to 40.00±7.9mg/dL, respectively. Afterwards, bakery products,
bread, cookies and chapatti were prepared by using 0.5 and 1% concentration of F/Gm
and G/Gm model systems. Acrylamide concentration was determined in bread by using
GC-MS and it was found that minimum value of acrylamide (0.07±0.08μg/g) was
recorded in T 4 (1% pectin-treated F/Gm model system). Acrylamide content was
decreased from 1.93±1.9 to 0.88±1.5μg/g during the entire study. In cookies, minimum
acrylamide concentration (0.09±0.09μg/g) was recorded in T 4 (1% pectin-treated F/Gm
model system). The acrylamide content was decreased from 1.17±1.6 to 0.52±0.6μg/g
during the entire study. In chapattis, high acrylamide concentration (2.39±0.35μg/g) was
observed in T 0 (control). Conversely, minimum value of acrylamide concentration
(0.11±0.10μg/g) was recorded in T 4 (1% pectin-treated F/Gm model system). Acrylamide
content was reduced from 1.4±0.9 to 0.80±0.8μg/g during the entire storage period in
chapattis. So, it is concluded that pectin-treated model systems reduced higher quantity of
acrylamide content as compared to other mitigation strategies.