Abstract:
In this thesis, the shear properties of High Strength Reinforced Concrete (HSRC)
beams have been investigated on the basis of available research data and
experimental work at Structural Laboratories of University of Engineering and
Technology Taxila-Pakistan. The shear capacity of High Strength Reinforced
Concrete (HSRC) beams is relatively less investigated in the contemporary
research, as most of the research data available is based on the results from
normal strength reinforced concrete with compressive strength of 40MPa or less.
There is a general consensus amongst the researchers in the field of Structural
Engineering and Concrete Technology that the shear strength of HSRC beams,
unlike the Normal Strength Reinforced Concrete (NSRC) does not increase, in
the same proportion as the increase in the compressive strength of concrete, due
to brittle behaviour of the High Strength Concrete. Hence the current empirical
equations proposed by most of the building and bridges codes for shear strength
of HSRC beams are less conservative as compared to the Normal Strength
Reinforced Concrete (NSRC) beams. This major observation by the researchers
is the main focus of this research.
An extensive literature review of the shear properties of Normal Strength
Reinforced Concrete (NSRC) beams and High Strength Reinforced Concrete
(HSRC) beams was undertaken. Additionally the shear strength of disturbed
region (D-Region) was also studied. In disturbed region the ordinary beams
theory based on Bernoulli’s theorem is not applicable. In the literature review of
disturbed regions special emphasis was laid over Strut and Tie Model (STM),
which is an emerging analysis and design tool in the current research in
reinforced concrete.
The literature review was followed by the experimental work, which comprised of
70 high strength reinforced concrete beams and 9 two ways high strength
concrete cobles. Beams were cast in two sets of 35 beams each, one set without
web reinforcement and other with web reinforcement. For each set of 35 beams
3five values of longitudinal reinforcement and seven values of shear span to depth
ratio were selected to mainly study the behaviour of slender beams, where
typical shear failure can be anticipated. These beams were tested under
monotonic load at the mid span to examine the contribution of various
parameters like longitudinal steel, shear span to depth ratio, and web
reinforcement, on the shear capacity of HSRC beams. It has been observed that
the shear strength of beams has been increased with the increase in longitudinal
steel and shear reinforcement but it has reduced with the increase in the shear
span to depth ratio. The beams with low longitudinal steel ratio and no web
reinforcement failed mainly due to shear flexure cracks. However the beams with
longitudinal steel ratio of 1% and more failed mainly due to beam action in shear
tension failure. The beams with small shear span to depth ratio and large values
of longitudinal steel ratio however failed due to shear compression failure.
The shear failure of HSC beams with large values of longitudinal steel and shear
span to depth ratio was however more sudden and brittle, giving no sufficient
warning before failure, which has been observed as serious phenomena in the
shear failure of HSC beams.
The addition of web reinforcement increased the shear strength of all beams
tested. The failure mode was also affected. The obvious contribution of the
minimum web reinforcement was avoiding the sudden failure of the HSC beams.
These test results were also compared with the equations of some international
building and bridges codes and methods for shear strength of HSRC beams. It
has been noticed that these equations do not provide equal level of safety in the
shear design of HSRC beams. Some of the codes are over conservative, while
few others are less conservative for the shear design of HSRC beams.
Comparison of the observed shear strength of tested HSRC beams with the
results of the codes equations used, reveal that most of these equations are less
conservative for shear design of HSRC beams at lower values of longitudinal
steel for both cases of beams with and without web reinforcement, particularly for
4longitudinal steel ratio less than1%. Hence additional care may be required for
shear design of HSRC beams at large values of shear span to depth ratios.
To analyze the behaviour of typical disturbed region in concrete structures, the
basic rationale of Strut and Tie Model (STM) was used for the analysis and
design of two way corbels. These corbels were tested under monotonic loads
applied at the overhanging portion of the corbels. The actual shear capacities of
these corbels were compared with the theoretical shear capacities of the corbels
worked out with the STM. The actual and theoretical values of the shear were
falling close to each other. Their comparison reveals that STM can be further
tested as more simple and reliable tool for analysis and design of disturbed
region (D-Region) in concrete structures, through more experimental research.
Further research work on shear properties of HSRC beams with higher values of
compressive strength of concrete in the beam region and more experimental
research on the disturbed region including pile caps, deep beams, dapped ended
beams and corbels has been recommended at Engineering University-Taxila
Pakistan.